How long before a waterproofing system can be flood-tested?

Use the milestone for flood testing, not a generic dry-to-touch time. The table below is built only from numeric times in manufacturer documents already recorded in our catalog.

Important: Shortest does not mean interchangeable. Product type, surface, conditions and intended use still have to match your project.

Manufacturer-stated times

ProductManufacturer-stated minimumCondition/source
LATICRETE HYDRO BAN 1
One-part liquid membrane (DS-65452-1026)
2 hoursAt 70°F (21°C) and 50% relative humidity. For 35 to 69°F (2 to 21°C), allow 24 hours after final cure.
LATICRETE HYDRO BAN Adhesive & Sealant
Sealant (DS-108-0825)
2 hoursAt 70°F (21°C) or higher and 50% relative humidity. Cold or dry conditions require a longer cure.
MAPEI Mapelastic AquaDefense
Liquid-applied membrane
12 hoursConditions are not stated beyond the shower-pan use.
LATICRETE 9235 Waterproofing Membrane
Liquid membrane (DS-236-0420)
7 daysAt 70°F (21°C) and 50% relative humidity. Cold and wet conditions need longer.

How to use this table

Open the exact product page to see the variant, source wording, stated conditions and other milestones. A minimum time is the earliest stated threshold under the manufacturer’s conditions—not a guarantee for colder, wetter, thicker or poorly ventilated applications.

Related checks

  • Confirm the exact formula and region on your container.
  • Use the clock for your next action rather than touch-dry time.
  • Check temperature, humidity, thickness and substrate notes.
  • When the manufacturer provides no correction factor, wait longer and verify physical readiness.